Downloads
Bondix Software Downloads
This page provides download links for Bondix software compatible with various devices and firmware versions. Select the appropriate file based on your device model and firmware version.
Current Release Version: 1.25.7
⚠️ | By initiating the download of the software from this site, you hereby acknowledge and consent to be bound by the terms of our End User License Agreement (EULA) and Terms of Use, which constitute a legally binding contract between you and SIMA GmbH.
Please review these documents carefully prior to downloading. |
---|
Client
Teltonika Routers
Packages
Model Series | Supported Routers | Download
(RUTOS version) |
---|---|---|
RUTX | RUTX08, RUTX09, RUTX10, RUTX11, RUTX12, RUTX14, RUTX50, RUTXR1 | 00.07.14.3 |
RUTM | RUTM08, RUTM09, RUTM10, RUTM11, RUTM50, RUTM51, RUTM52, RUTM54, RUTM59 | 00.07.14.3 |
RUT9M | RUT901, RUT906, RUT951, RUT956 | 00.07.14.3 |
RUT2M | RUT200, RUT241, RUT260 | 00.07.14.3 |
RUTC | RUTC50 | 00.07.14.3 |
RUTE | RUT206, RUT271 | 00.07.14.3 |
EOL
For routers designated as "End of Production" by Teltonika Networks, we no longer provide updated Bondix Client versions. If your device is marked as EOL and you require further support or newer versions, please contact us directly via email.
Advantech
Please contact our support team via our Support Portal.
Server
Current Version (1.25.7)
Download and execute this script on your server.
Proceed to Installing a Bondix Server.
Previous Version (1.24.1.9)
Note: With the release of version 1.25.x, significant changes have been introduced. For users who may need it, we've made the previous version available which continues to receive critical fixes. However, please be aware that downgrading from version 1.25.x to this earlier release is not supported.
We provide only the server component for this version. The client software should always be kept up to date. If you believe you need an older client version, please reach out to us.
Changelog
1.25.7
- Resolved a rare issue where malformed SSL communication could trigger a watchdog-initiated restart of the Bondix server process.
- Fixed an issue where disconnecting one channel could inadvertently cause another channel to disconnect within the same environment.
- Server-Tunnel Settings: Disable Transparent Bonding Proxy; users can now disable the transparent Bonding Proxy in environments where it is enabled by default.
- Server-Tunnel Settings: Generate Connection String; added the ability to generate a connection code on the Servers tunnel settings, that simplifies the configuration of Bondix clients.
- Server-Tunnel Settings: Global Packet Size Configuration; introduced a (tunnel) global setting to define the packet size for Bondix payloads across all active channels. (Note: This is not the same as MTU size.)
- Server-Environment Settings: Bind Proxy to Outgoing Interface; ensures that traffic always uses the Bondix server’s outgoing interface, even if the destination network is reachable via another tunnel or environment on the same server. This setting needs to be disabled for LAN-to-LAN traffic.
- Server-Environment Settings: Isolate Environment; allows complete isolation of an environment from incoming traffic. Caution: This will disable TCP port forwarding and the Transparent Bonding Proxy.
1.25.3
- Initial IPv6 support
- Prometheus Support
- New Unified Client UI
- Support for latest Teltonika RUTOS firmwares
- Many bugfixes and performance improvements
1.24.1.9
- Fixed an issue where a channel disconnect could cause an unrelated channel to disconnect as well
1.24.1.8
- Improved detection for stuck flows
- Fix issue where some outgoing protocol packets would not be sent, which would be reported as lost packets
- Fix interface selection by ignoring channels with unknown latency
Versions 1.24.1.6 & 1.24.1.7 were just for internal testing and/or have been retracted.
1.24.1.5
- Added support for Teltonika RutOS 07.07.3.
- Previous fix for 'no traffic after last remaining channel disconnect' was incomplete; the issue could still trigger in rare circumstances. Additionally, client and server now have detection mechanisms to identify if the remote side is affected by this or similar issues.
1.24.1.4
- Added support for Teltonika RUTOS 07.07.1 and 07.06.11
- Fixed "No error message was provided" message in Bondix Client log when using Cloudlink. The message was always shown despite no error being reported. Functionality was unaffected.
1.24.1.3
- Fixed a rare crash that could arise in very specific situations when writing data to a socket
- Add environment & Uptime in statistics/SNMP
- Fixed an issue where certificate based tunnels were not removed despite set-tunnel-autoremove being configured, when the initial tunnel handshake never completed
- add tunnel name as parameter when calling tunnel-tapconnect/tunnel-tapdisconnect
- In some place an argument would be passed to OpenSSL without checking whether the argument is valid, potentially resulting in a crash.
1.24.1.2
- Fixed an issue where traffic would no longer pass through the tunnel after the last remaining channel disconnected and reconnected without triggering a tunnel reset.
- Fixed an issue on Teltonika where DSCP values in the QoS editor would not be saved.
- On Teltonika, the client will now automatically restart after 5 minutes of tunnel downtime. The behavior of the underlying “set-restart-on-failure" configuration command has been fixed.
- Added metrics for connection attempts and active BondingProxy connections. The number of active proxy connections can now be observed in the monitor.
- Added support for Teltonika RutOS 07.06.6.
Release Notes
- August 2023
- June 2023
- May 2023
- April 2023
- January 2023
- December 2022
- November 2022
- October 2022
- September 2022