Client/Quickstart

From Bondix Wiki


Basic instructions for installing the S.A.NE client on your RUTX12.

It is recommend reset all router settings before you start the installation 1) Please check that the RUTX12 is running the version RUTX_R_00.02.06.1. If not, download and install it from here: https://wiki.teltonika-networks.com/wikibase/images/6/62/RUTX_R_00.02.06.1_WEBUI.bin 2) Download the latest S.A.NE Client here:

https://releases.bondix.dev/files/saneclient-armv7-202112031459-84c5b697.ipk



3) Go to Packet Manager and install the S.A.NE client













Please also check that no Teltonika load balancing functionality is active on the router since this will have a massive impact on the performance:


















Also make sure that you have configured DNS forwarding to 8.8.8.8 and 9.9.9.9 to receive DNS through the tunnel:




















The general settings for the Bondix client should be set as follows:




"Tunnel" and "Password" should contain the credentials you received via email.

Please leave the “Backup Server” empty for now since this would require identical tunnel names on both servers to work

Once you entered the credentials please press "save and apply" and "restart service" afterwards

You can enter the IP of the Backup server here to is you have created one.

Tunnel Preset "Bonding"
















WAN interfaces

If you are using 2 LTE and you want them used evenly, please use the following settings:




If you do changes here, please always press "save and apply" and "update interface configuration". If you are also changing priority settings, please also press "restart service" so the new rules are also applied correctly on the server













Please check that the advanced settings are set as follows:





To enable the local Bondix debug Web interface



Attention: Settings here are not persistent and for debugging only. The Web interface does not work with Apple Safari, please use Chrome, Egde or Firefox instead



Enable debug Web interface to "on"

Debug listener IP (your IP of the Teltonika Web interface, standard is 192.168.1.1)

Define a listener port (I always use "8088"

Define a password (I always us something like "123456" since it is only local

press "save and apply"

press "restart service" in the general settings









If everything was set correctly you should get this page:




Here you enter your tunnel name and the password you set for the debug Web interface:







Press "Senden" to log into the Bondix Web interface



It will show you a graphical overview of the data traffic and connection status of the connected links